Project Description

Pen MEAS

These electrode arrays are typically arranged as 32, 36 and 64 grids for recording electrical signals. Obtained signals will be amplified by a filter amplifier and sent to a data acquisition computer. MappingLab offers microelectrodes with different sizes to match the size of samples. They are applicable to record electrical activation and excitation of perfused cardiac tissues in chamber or a whole heart from mouse, rat, Guinea pig, rabbit, sheep and dog in vivo and ex vivo. It can be stably mounted on the ball-joint holder to probe the samples from multiple angles. They are suitable to measure direction and velocity of conduction system as well as to monitor electrical activities from cultured pacing tissues. More excitedly, they can be used in drug testing and safety.

PA01604040301

Cat.36-1631

lattice :4  x  4       Electrode head  size :1.5 mm  x  1.5 mm        Electrode tip diameter :3.3 mm  x 3.3 mm

PA01604040302

Cat.36-1632

lattice :4  x  4       Electrode head  size :2 mm  x  2 mm        Electrode tip diameter :3.8 mm  x 3.8 mm

PA01604040303

Cat.36-1633

lattice :4  x  4       Electrode head  size :3 mm  x  3 mm        Electrode tip diameter :4.8 mm  x 4.8 mm

PA01604040305

Cat.36-1635

lattice :4  x  4       Electrode head  size :5 mm  x  5 mm        Electrode tip diameter :6.8 mm  x 6.8 mm

PA03206060301

Cat.36-3231

lattice :6  x  6       Electrode head  size :1.5 mm  x  1.5 mm        Electrode tip diameter :3.3 mm  x 3.3 mm

PA03206060302

Cat.36-3232

lattice :6  x  6       Electrode head  size :2 mm  x  2 mm        Electrode tip diameter :3.8 mm  x 3.8 mm

PA03206060303

Cat.36-3233

lattice :6  x 6       Electrode head  size :3 mm  x  3 mm        Electrode tip diameter :4.8 mm  x  4.8 mm

PA03206060306

Cat.36-3234

lattice :6  x 6       Electrode head  size :6 mm  x  6 mm        Electrode tip diameter :7.7 mm  x  7.7 mm

PA03606060301

Cat.36-3631

lattice :6  x 6       Electrode head  size :1.5 mm  x  1.5 mm        Electrode tip diameter :3.3 mm  x  3.3 mm

PA03606060302

Cat.36-3632

lattice :6  x 6       Electrode head  size :2 mm  x  2 mm        Electrode tip diameter :3.8 mm  x  3.8 mm

PA03606060303

Cat.36-3633

lattice :6  x 6       Electrode head  size :3 mm  x  3 mm        Electrode tip diameter :4.8 mm  x  4.8 mm

PA03606060306

Cat.36-3634

lattice :6  x 6       Electrode head  size :6 mm  x  6 mm        Electrode tip diameter :7.7 mm  x  7.7 mm

PA06408080301

Cat.36-6431

lattice :8  x  8       Electrode head  size :1.5  mm  x  1.5  mm        Electrode tip diameter :3.3 mm  x 3.3  mm

PA06408080302

Cat.36-6432

lattice :8  x  8       Electrode head  size :2  mm  x  2  mm        Electrode tip diameter :3.8 mm  x 3.8 mm

PA06408080303

Cat.36-6433

lattice :8  x  8       Electrode head  size :3  mm  x  3  mm        Electrode tip diameter :4.8 mm  x 4.8 mm

PA06408080306

Cat.36-6434

lattice :8  x  8       Electrode head  size :6  mm  x  6  mm        Electrode tip diameter :7.7 mm  x 7.7 mm

PA06408080308

Cat.36-6435

lattice :8  x  8       Electrode head  size :8  mm  x  8  mm        Electrode tip diameter :9.1 mm  x 9.1 mm

Multielectrode Arrays

Our unique innovative pen electrodes are ideal for studying electric signals on the surface of isolated Langendorff perfused hearts. Various types of multielectrode arrays with high precision such as flat electrodes and glass microelectrode arrays are customised for cardiac researchers who need particular designs for their experiments.

Related Tags:

Multielectrode arrays      pen electrodes      flat electrodes       soft electrodes      glass multielectrode arrays        electrodes for incubator      customised electrodes